Search results for "Clinical Chemistry Tests"

showing 4 items of 4 documents

An inter-laboratory validation of methods of lipid peroxidation measurement in UVA-treated human plasma samples

2010

Lipid peroxidation products like malondialdehyde, 4-hydroxynonenal and F2-isoprostanes are widely used as markers of oxidative stress in vitro and in vivo. This study reports the results of a multi-laboratory validation study by COST Action B35 to assess inter-laboratory and intra-laboratory variation in the measurement of lipid peroxidation. Human plasma samples were exposed to UVA irradiation at different doses (0, 15 J, 20 J), encoded and shipped to 15 laboratories, where analyses of malondialdehyde, 4-hydroxynonenal and isoprostanes were conducted. The results demonstrate a low within-day-variation and a good correlation of results observed on two different days. However, high coefficie…

Ultraviolet RaysClinical Chemistry TestsEnzyme-Linked Immunosorbent AssayIsoprostanesmedicine.disease_causeF2-isoprostanesSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyMass Spectrometry4-HydroxynonenalLipid peroxidationPlasmachemistry.chemical_compoundIn vivoMalondialdehydemedicineHumansChromatography High Pressure LiquidAldehydesChromatographyChemistryReproducibility of Resultsoxidative stress; F2-Isoprostanes; 4.-hydroxynonenal; malondialdehydeGeneral MedicineOxidative stress; F2-isoprostanes; 4-hydroxynonenal; malondialdehydeMalondialdehydeIsoprostanes4-hydroxynonenalF2-IsoprostanesBiochemistryOxidative stressLipid PeroxidationOxidative stressChromatography Liquid
researchProduct

Sample preparation strategies for the determination of psychoactive substances in biological fluids

2020

This review focuses on the existing analytical procedures for the determination of new psychoactive substances (NPS) in biological fluids by chromatographic methods. Direct analysis of samples is scarcely employed and most proposed methodologies include a sample pre-treatment in order to remove matrix interferents and, in some cases, pre-concentrate extracts. Current extraction methods for NPS determination in plasma/serum, urine, and oral fluids have been widely discussed, such as liquid-liquid, solid-phase, and micro extraction approaches, highlighting the advantages and drawbacks of the proposed extraction methodologies. Regarding microextraction approaches, techniques like microextracti…

SorbentLiquid Phase MicroextractionLiquid-Liquid ExtractionClinical Chemistry Tests010402 general chemistry01 natural sciencesBiochemistrySpecimen HandlingAnalytical ChemistryMatrix (chemical analysis)Liquid chromatography–mass spectrometryBiological fluidsHumansSample preparationSolid phase extractionSalivaSolid Phase MicroextractionChromatographyPsychotropic DrugsChromatographyChemistrySolid Phase Extraction010401 analytical chemistryOrganic ChemistryExtraction (chemistry)General MedicineBody Fluids0104 chemical sciencesAnalytical proceduresJournal of Chromatography A
researchProduct

“Ultra-sensitive” cardiac troponins: Requirements for effective implementation in clinical practice

2018

The measurement of cardiac troponins, either cardiac troponin I or T, has become the culprit of clinical decision making in patients with suspected acute coronary syndrome (ACS), especially in those with non-ST elevation myocardial infarction (NSTEMI). The leading analytical mainstays of cardiac troponin immunoassays include the limit of blank (LoB), limit of detection (LoD), functional sensitivity, the 99th percentile of a healthy reference population, along with the percentage of “ostensibly healthy” subjects displaying measurable values 50% in the general healthy population. The very recent commercialization of methods with further improved analytical sensitivity (i.e., “ultra-sensitive”…

medicine.medical_specialtyAcute coronary syndromeCardiac troponinClinical BiochemistryClinical Chemistry TestsReview030204 cardiovascular system & hematologyCulpritacute coronary syndromecardiac troponin; myocardial infarction; acute coronary syndrome; diagnostics03 medical and health sciences0302 clinical medicineTroponin TLimit of DetectionInternal medicinecardiac troponinmedicinediagnosticsHumansIn patient030212 general & internal medicineMyocardial infarctionUltra sensitiveacute coronary syndrome; cardiac troponin; diagnostics; myocardial infarctionbusiness.industryHealthy populationBiochemistry (medical)Troponin Imedicine.diseaseClinical Practicemyocardial infarctionCardiologybusinessAlgorithmsBiochemia Medica
researchProduct

Assessment of the statistical significance of classifications in infrared spectroscopy based diagnostic models.

2014

Fourier transform infrared (IR) spectroscopy in combination with multivariate data analysis is a versatile tool that can be applied to disease diagnosis. However, a rigorous validation of the obtained models is necessary in order to obtain robust results. This work evaluates the advantages of the use of permutation testing for determining the statistical significance of the misclassification errors obtained from IR based diagnostic models through cross validation (CV). The model performance, estimated by CV, is compared to a distribution of CV-performance values obtained using randomly permuted class labels. The distribution of ‘random CV-values’ is considered as a null distribution and use…

Multivariate analysisFeature selectionClinical Chemistry Tests02 engineering and technology01 natural sciencesBiochemistryCross-validationAnalytical ChemistryResamplingStatisticsDiagnosisSpectroscopy Fourier Transform InfraredElectrochemistryNull distributionEnvironmental ChemistryHumansSpectroscopyMathematicsModels Statistical010401 analytical chemistryEstimatorContrast (statistics)Discriminant AnalysisReproducibility of Results021001 nanoscience & nanotechnology0104 chemical sciencesRandom forest0210 nano-technologyThe Analyst
researchProduct